100 GPD 5 - Stage Reverse Osmosis Replacement Filter Set - H2O Warehouse

ULP-1812 100GPD Reverse Osmosis Replacement Water Filter Membrane

The ULP-2012 Reverse Osmosis Replacement Water Filter Membrane, 100GPD is designed for reliability, ensuring your water is...
Availability: In stock
Product type: Water Filter
R 260.36
R 399.00
R 260.36
Please hurry! Only 17 left in stock
Subtotal: R 260.36
10 customers are viewing this product

Shipping & Delivery

Orders are normally processed within 3–5 business days. Choose Express at checkout, where available, for faster courier delivery after dispatch. Shipping options, rates and any delivery estimates are shown at checkout.

Special Delivery Requests / Notes

All 4m & 6m pipe lengths will be cut into 2m lengths for courier delivery. If you require full lengths please email us with your order number and request.

Discounts %

Note: Not all discounts can be compounded, one discount can be applied to an order at a time.
100 GPD 5 - Stage Reverse Osmosis Replacement Filter Set - H2O Warehouse

ULP-1812 100GPD Reverse Osmosis Replacement Water Filter Membrane

R 399.00 R 260.36

ULP-1812 100GPD Reverse Osmosis Replacement Water Filter Membrane

R 399.00 R 260.36

The ULP-2012 Reverse Osmosis Replacement Water Filter Membrane, 100GPD is designed for reliability, ensuring your water is filtered effectively and efficiently.

ULP-2012-100 reverse osmosis membrane
Removes 99% of biological contaminants such as bacteria, protozoa, giardia, cryptosporidium & protozoan cysts
Suitable for all domestic RO units
This membrane is NSF/ANSI standard tested 58 & certified
Comprised of a thin film composite RO membrane with a 50 gallon per day rating

Applications:

Residential drinking water
Laboratory water
Domestic RO systems
Whole-house water purification systems
Cooling tower water recycles
Desalination

Product specifications:

Average lifespan: 12-24 months

Important: Installation & Flushing

  • Isolate water and power (where fitted), then release pressure before servicing.
  • Remove only the membrane's external shipping packaging. Do not unwind the element or remove permanent wrapping, fittings or seals.
  • If carbon pretreatment is fitted: New carbon releases dust that can block taps, aerators, strainers, downstream filters and other equipment.
  • At first use and after carbon replacement, route flushing water directly to a bucket or open drain, bypassing downstream equipment via the manufacturer's approved flushing connection.
  • Where an RO membrane is fitted downstream, protect it using the model's separate-prefilter or assembled-system flushing procedure. Do not improvise bypasses or run pumps dry; complete membrane and system start-up flushing.
  • Clear water is not proof of drinking-water safety; follow all feed-water, disinfection and commissioning requirements.