Katalox Light® Media FRP Vessel 18x65 – Automatic Backwash Complete with Media - H2O Warehouse
AFM® Media FRP Vessel 12x52 – Automatic Backwash Complete with Media - H2O Warehouse

Katalox Light Iron & Manganese Removal Filter – 18×65 FRP Vessel – Automatic Backwash

The 18×65 iron and manganese removal filter uses a manganese-dioxide-coated medium to support the oxidation and filtration...
Availability: In stock
Product type: Water Filter Vessel
R 28,506.50
R 37,850.00
R 28,506.50
Please hurry! Only 15 left in stock
Subtotal: R 28,506.50
10 customers are viewing this product

Shipping & Delivery

Orders are normally processed within 3–5 business days. Choose Express at checkout, where available, for faster courier delivery after dispatch. Shipping options, rates and any delivery estimates are shown at checkout.

Special Delivery Requests / Notes

All 4m & 6m pipe lengths will be cut into 2m lengths for courier delivery. If you require full lengths please email us with your order number and request.

Discounts %

Note: Not all discounts can be compounded, one discount can be applied to an order at a time.
Katalox Light® Media FRP Vessel 18x65 – Automatic Backwash Complete with Media - H2O Warehouse

Katalox Light Iron & Manganese Removal Filter – 18×65 FRP Vessel – Automatic Backwash

R 37,850.00 R 28,506.50

Katalox Light Iron & Manganese Removal Filter – 18×65 FRP Vessel – Automatic Backwash

R 37,850.00 R 28,506.50

The 18×65 iron and manganese removal filter uses a manganese-dioxide-coated medium to support the oxidation and filtration of iron and manganese. It can also form part of a treatment system for hydrogen sulphide, subject to water analysis and the required oxidation process.

This complete media-vessel package includes the 18×65 FRP vessel, Runxin automatic backwash valve and Katalox Light catalytic filtration media.


Key Features & Benefits

  • Targeted treatment: Helps reduce iron and manganese associated with staining and deposits in water systems.
  • Catalytic filtration: Supports the conversion and capture of dissolved contaminants when the water chemistry and oxidant conditions are suitable.
  • Downstream protection: Can reduce metal loading ahead of further filtration, softening or reverse osmosis.
  • Automatic backwash: A programmed cleaning cycle reduces hands-on valve operation. The inlet supply and waste drain must still provide the required backwash capacity.
  • FRP construction: A corrosion-resistant vessel body houses the treatment bed.

Applications

  • Borehole and wellpoint water with confirmed iron or manganese contamination.
  • Point-of-entry treatment and selected commercial processes, sized to the tested water quality.
  • Pre-treatment ahead of downstream equipment where iron or manganese reduction is required.

Technical Specifications

  • Product code: H2OW1203
  • Vessel size designation: 18×65; nominal vessel designation, not the installed height including the valve.
  • Vessel material: Fibreglass-reinforced plastic (FRP).
  • Treatment media: Katalox Light catalytic filtration media
  • Head / control: Runxin automatic backwash valve
  • Media inlet pH range: 5.8–10.5 is the manufacturer’s media range; the required treatment pH depends on the contaminants present.
  • System design flow: Select from the water analysis, media bed depth, required outlet quality and available backwash supply. Vessel size or valve capacity alone does not establish the treatment flow.

What’s Included

  • Vessel: 1 × 18×65 FRP vessel.
  • Control valve: 1 × Runxin automatic backwash valve.
  • Media: 5 × 30 kg bags of Katalox Light media (150 kg supplied).
  • Internals: Riser pipe and distribution components as specified for this vessel.

Installation & Use

  • Before installation: Have the source water tested and confirm the treatment sequence, operating flow and backwash requirements.
  • Site connections: Arrange inlet and outlet pipework, suitable isolation/bypass provision and a correctly sized drain for backwash water.
  • Commissioning: Load and condition the media according to the media and valve instructions. Leave the required expansion space; supplied bag quantities are not an instruction to fill the vessel to the top.
  • Cleaning control: Programme the valve for the site’s water quality and follow the fitted valve instructions.
  • Operating limits: Use the lowest pressure and temperature limits of the vessel, valve and other fitted components. Isolate and depressurise before opening the vessel.

Important Information

  • Water chemistry: Confirm pH, iron, manganese, dissolved oxygen and any hydrogen sulphide before selection. Manganese treatment can need higher pH and more contact time than iron treatment.
  • Oxidation: Aeration or a controlled oxidant stage may be required. Backwashing alone does not replace the necessary oxidation conditions.
  • Media maintenance: Backwash and rinse to clear retained solids; monitor treated-water quality and pressure loss.
  • Complete treatment design: Additional oxidation, pH correction, softening or disinfection may be required for the intended use. A media vessel alone does not establish that water is suitable for drinking.