AFM® Media FRP Vessel 12x52 – Automatic Backwash Complete with Media - H2O Warehouse
AFM® Media FRP Vessel 12x52 – Automatic Backwash Complete with Media - H2O Warehouse

AFM Sediment & Turbidity Reduction Filter – 12×52 FRP Vessel – Automatic Backwash

The 12×52 sediment and turbidity reduction filter captures suspended particles to improve water clarity. AFM is activated...
Availability: In stock
Product type: Water Filter Vessel
R 9,445.00
R 10,139.00
R 9,445.00
Please hurry! Only 4 left in stock
Subtotal: R 9,445.00
10 customers are viewing this product

Shipping & Delivery

Select from shipping options at Check Out - Shipped & Delivered Within 2- 5 Business Days

Special Delivery Requests / Notes

All 4m & 6m pipe lengths will be cut into 2m lengths for courier delivery. If you require full lengths please email us with your order number and request.

Discounts %

Note: Not all discounts can be compounded, one discount can be applied to an order at a time.
AFM® Media FRP Vessel 12x52 – Automatic Backwash Complete with Media - H2O Warehouse

AFM Sediment & Turbidity Reduction Filter – 12×52 FRP Vessel – Automatic Backwash

R 10,139.00 R 9,445.00

AFM Sediment & Turbidity Reduction Filter – 12×52 FRP Vessel – Automatic Backwash

R 10,139.00 R 9,445.00

The 12×52 sediment and turbidity reduction filter captures suspended particles to improve water clarity. AFM is activated glass filter media used as a physical filtration stage, with routine backwashing to remove accumulated material from the bed.

This complete media-vessel package includes the 12×52 FRP vessel, Runxin automatic backwash valve and AFM activated glass filter media.


Key Features & Benefits

  • Clearer water: Reduces suspended sediment and particulate matter responsible for turbidity.
  • Activated glass media: Provides a filtration bed designed to resist biofouling when correctly operated.
  • Useful pre-filtration: Helps reduce particulate loading on downstream cartridges and other treatment equipment.
  • Automatic backwash: A programmed cleaning cycle reduces hands-on valve operation. The inlet supply and waste drain must still provide the required backwash capacity.
  • FRP construction: A corrosion-resistant vessel body houses the treatment bed.

Applications

  • Sediment filtration for borehole, wellpoint, rainwater and municipal supplies, following a water-quality assessment.
  • Point-of-entry filtration and suitable commercial water processes.
  • Pre-filtration before fine cartridges, UV or reverse osmosis where required by the treatment design.

Technical Specifications

  • Product code: H2OW1223
  • Vessel size designation: 12×52; nominal vessel designation, not the installed height including the valve.
  • Vessel material: Fibreglass-reinforced plastic (FRP).
  • Treatment media: AFM activated glass filter media
  • Head / control: Runxin automatic backwash valve
  • System design flow: Select from the water analysis, media bed depth, required outlet quality and available backwash supply. Vessel size or valve capacity alone does not establish the treatment flow.

What’s Included

  • Vessel: 1 × 12×52 FRP vessel.
  • Control valve: 1 × Runxin automatic backwash valve.
  • Media: AFM activated glass filter media supplied for this product configuration.

Installation & Use

  • Before installation: Have the source water tested and confirm the treatment sequence, operating flow and backwash requirements.
  • Site connections: Arrange inlet and outlet pipework, suitable isolation/bypass provision and a correctly sized drain for backwash water.
  • Commissioning: Load and condition the media according to the media and valve instructions. Leave the required expansion space; supplied bag quantities are not an instruction to fill the vessel to the top.
  • Cleaning control: Programme the valve for the site’s water quality and follow the fitted valve instructions.
  • Operating limits: Use the lowest pressure and temperature limits of the vessel, valve and other fitted components. Isolate and depressurise before opening the vessel.

Important Information

  • Treatment role: AFM captures particles. Dissolved iron or manganese generally requires an oxidation stage before the resulting solids can be filtered.
  • Filtration performance: Particle capture depends on the AFM grade, media layering, filtration velocity and feed water. The vessel is not assigned an absolute micron rating here.
  • Water hygiene: Resistance to biofouling in the media does not mean the water is disinfected. Provide a separately designed disinfection stage where required.
  • Bed care: Use the specified media grading, support arrangement and expansion space; backwash at a flow that cleans the bed without washing media out.
  • Complete treatment design: Additional oxidation, pH correction, softening or disinfection may be required for the intended use. A media vessel alone does not establish that water is suitable for drinking.