{"product_id":"tesk-svm-t10-100-twin-pump-booster-skid","title":"8 kW TESK SVM(T)10-100 Twin-Pump Booster Skid | 2 x 4 kW","description":"\u003cp\u003eThe TESK SVM(T)10-100 twin-pump booster skid combines two vertical multistage pumps on a common galvanised base for a project-specific water-pressure boosting installation. This listing represents one complete two-pump assembly. Each pump has a documented operating point of 10 m³\/h at 81.5 m head; the final system duty must be checked against the installation requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply unit:\u003c\/strong\u003e One skid containing two TESK SVM(T)10-100 pumps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-pump motor:\u003c\/strong\u003e 4 kW, 380 V, three-phase, 50 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly:\u003c\/strong\u003e Common base, shared flanged pipework, valves and pump-mounted control enclosures, as shown in the reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e DN40 DIN PN25 flanged connections are stated for each pump; confirm complete-skid connection sizes before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Download the skid overview and separate single-pump performance curves below.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe assembly brings two matching pump units, their visible control enclosures and common pipework together on one base. The SVM(T)10-100 is a non-self-priming vertical multistage centrifugal pump with inline inlet and outlet connections. The supplied technical reference identifies ten stages and a nominal speed of 2900 rpm.\u003c\/p\u003e\n\u003cp\u003eA two-pump arrangement must be selected with its actual control sequence and hydraulic duty in mind. Duty\/standby operation and simultaneous operation give different system behaviour. The supplied curve describes one pump; it does not establish the complete skid's output. A verified combined curve, control settings and site requirements must determine the final selection.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo matching SVM(T)10-100 pump units on a shared fabricated skid.\u003c\/li\u003e\n\u003cli\u003eVertical multistage construction with documented 304 stainless steel impellers.\u003c\/li\u003e\n\u003cli\u003eIndividual motor ratings of IP55 protection and class F insulation.\u003c\/li\u003e\n\u003cli\u003eVisible flanged manifold arrangement, blue-handled valves and interconnecting wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e A common base keeps the two-pump assembly together for coordinated site installation.\u003c\/li\u003e\n\u003cli\u003e Matching pumps provide a consistent model reference for technical selection and service planning.\u003c\/li\u003e\n\u003cli\u003e Included pump curves and drawings help the installer check the proposed operating point before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump quantity and model:\u003c\/strong\u003e 2 x TESK SVM(T)10-100.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed duty per pump:\u003c\/strong\u003e 10 m³\/h at 81.5 m head, 2900 rpm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor per pump:\u003c\/strong\u003e 4 kW; 380 V; three-phase; 50 Hz; rated current 7.84 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStages:\u003c\/strong\u003e 10 per pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed pump efficiency:\u003c\/strong\u003e 64.1% at the stated operating point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-pump connections:\u003c\/strong\u003e DN40, DIN flange, PN25. This flange designation is not a complete-skid pressure rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurve conditions:\u003c\/strong\u003e Clean water at 20°C; the reference states ISO 9906 Grade 2 for clean cold water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePacked system weight and dimensions:\u003c\/strong\u003e Awaiting confirmation. Single-pump drawing dimensions and mass must not be used for freight booking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eFor consideration in engineered commercial water-pressure boosting systems where the documented pump curve matches the design duty. Selection requires peak demand, static lift, pipework losses, inlet conditions and required outlet pressure. Building height or room count alone does not confirm suitability.\u003c\/p\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne complete skid assembly containing two SVM(T)10-100 pumps.\u003c\/li\u003e\n\u003cli\u003eCommon base and the shared pipework, valves, control enclosures and wiring represented in the reference photograph, subject to the approved final bill of materials.\u003c\/li\u003e\n\u003cli\u003eDownloadable skid overview and single-pump technical reference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm installation, commissioning, delivery, external pipework, electrical connection and any additional controls separately in the project quotation.\u003c\/p\u003e\n\u003ch3\u003eCompatibility and Installation\u003c\/h3\u003e\n\u003cp\u003eBefore order release, confirm the controller nameplates, site electrical supply, skid connections, operating sequence, pressure limits and final component schedule. A qualified installer must check available suction conditions and the required duty against the complete system design.\u003c\/p\u003e\n\u003ch3\u003eMaintenance and Service\u003c\/h3\u003e\n\u003cp\u003eObtain the exact pump and controller installation and service instructions before commissioning. Confirm access for inspection, isolation and servicing in the site layout. No service interval or replacement-parts equivalence is established by the supplied performance sheet.\u003c\/p\u003e\n\u003ch3\u003eWhy Choose This Product\u003c\/h3\u003e\n\u003cp\u003eThis assembly brings two documented TESK multistage pumps into one packaged arrangement, with model-specific performance information available for engineering review.\u003c\/p\u003e\n\u003ch3\u003eTechnical Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0864\/2019\/3565\/files\/tesk-svm-t10-100-twin-pump-skid-datasheet.pdf?v=1793055377\" rel=\"noopener\" target=\"_blank\"\u003eTwin-pump skid overview and per-pump specifications (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0864\/2019\/3565\/files\/tesk-svm-t10-100-single-pump-performance.pdf?v=1793055038\" rel=\"noopener\" target=\"_blank\"\u003eSVM(T)10-100 single-pump curves, dimensions and structure drawing (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eImage disclaimer: The clean product image is an illustrative edit of the supplied warehouse photograph. Final supplied components are governed by the approved bill of materials.\u003c\/em\u003e\u003c\/p\u003e","brand":"TESK","offers":[{"title":"Default Title","offer_id":67880976515357,"sku":"H2OW1574","price":139540.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0864\/2019\/3565\/files\/8-kw-tesk-svmt10-100-twin-pump-booster-skid-2-x-4-kw-7470072.png?v=1793077627","url":"https:\/\/h2owarehouse.co.za\/products\/tesk-svm-t10-100-twin-pump-booster-skid","provider":"H2O Warehouse","version":"1.0","type":"link"}